<strong>Filter</strong> <strong>Housings</strong><br />

VF-61, VF-61E, VF-62<br />

Clean Dry Fuels and Oils with<br />

High Performance Aquacon ® <strong>Filter</strong> Cartridges<br />

FEATURES<br />

• Free and emulsified water to less than 5 ppm<br />

• 1/2 micrometer particulate removal<br />

• Provides protection against “slugs” of water<br />

• Pressure increase signals cartridge change<br />

• Use with existing filter housings<br />

DESCRIPTION<br />

The VF-61, and VF-62 are versatile filter housings<br />

designed for use with several different high performance<br />

Aquacon filter cartridges, as well as a variety of paper<br />

filters and coalescer/separator cartridges. Refer to the<br />

cartridge selection table on page 3.<br />

Aquacon cartridges filter out water by chemically locking<br />

it into layers of super-absorbent media. Water removal<br />

efficiency is not affected by common surfactants or<br />

additives. Water capacity is as much as 1 1 /2 quarts,<br />

depending on the flow rate. These cartridges also<br />

effectively filter out dirt, rust and other particulates.<br />

(See caution, page 4)<br />

As a cartridge reaches its water-holding limit, the media<br />

expands very rapidly and restricts the flow. For oils and<br />

other high viscosity liquids, the pressure drop will rapidly<br />

increase, signaling the need to change cartridges.<br />

The VF-61, with ACO series cartridges installed, has<br />

become the standard for low flow rate full flow aviation<br />

fuel monitor applications.<br />

Use the VF-61E with band clamp closure for areas with<br />

limited space.<br />

APPLICATIONS<br />

Jet Fuel<br />

Avgas<br />

Motor Gasoline<br />

Diesel Fuel<br />

Biodiesel Fuel<br />

Insulating Oil<br />

Hydraulic Oil<br />

Lubricating Oil<br />

Selected Solvents<br />

VF-61<br />

VF-61E<br />

with Band Clamp Closure<br />

VF-62<br />

Pictured with Optional<br />

Hand Knobs<br />

© 2011 <strong>Velcon</strong> <strong>Filter</strong>s, LLC. 2105-R1 10/11


DIMENSIONAL DRAWINGS<br />

Please note: Drawings are not to scale. Dimensions are shown for estimating purposes only.<br />

Allow 6 inches (15.2 cm) below the vessel to safely remove the vessel to gain access to the cartridge.<br />

5-7/16”<br />

(13.8cm)<br />

VF-61<br />

Bolts<br />

8-1/2”<br />

(22.2cm)<br />

3”<br />

(7.6cm)<br />

5-7/16”<br />

(13.8cm)<br />

VF-61E<br />

Clamp<br />

7-1/2”<br />

(19cm)<br />

3”<br />

(7.6cm)<br />

13/32” Dia<br />

(typ.)<br />

1-1/2” NPT<br />

13/32” Dia<br />

(typ.)<br />

20”<br />

(50.8cm)<br />

6”<br />

(15cm)<br />

Optional CK-1488 Handles<br />

When assembled, the outside<br />

length becomes 10” (25.4cm)<br />

1/8”NPT<br />

Vent x3<br />

20”<br />

(50.8cm)<br />

6”<br />

(15cm)<br />

1-1/2” NPT<br />

1/8”NPT<br />

Vent x3<br />

1/2” NPT<br />

Drain<br />

1/2” NPT<br />

Drain<br />

VF-61E has a band clamp closure. Use in<br />

areas with limited space.<br />

5-7/16”<br />

(13.8cm)<br />

VF-62<br />

Bolts<br />

8-1/2”<br />

(22.2cm)<br />

3”<br />

(7.6cm)<br />

13/32” Dia<br />

(typ.)<br />

1-1/2” NPT<br />

32-1/2”<br />

(81.92cm)<br />

6”<br />

(15cm)<br />

Optional CK-1488 Handles<br />

When assembled, the outside<br />

length becomes 10” (25.4cm)<br />

1/8”NPT<br />

Vent x3<br />

1/2” NPT<br />

Drain<br />

VF-62 has a longer body for areas and<br />

applications that require higher flow rate.


FILTER CARTRIDGE SELECTION TABLE<br />

Housing<br />

P/N<br />

VF-61,<br />

VF-61E<br />

VF-62<br />

Product<br />

being filtered<br />

Jet Fuel &<br />

Avgas (1)<br />

Application<br />

Cartridge<br />

P/N<br />

Data<br />

Sheet<br />

Type Micron<br />

ACO-512P3L<br />

Aquacon<br />

1681<br />

® 0.3 5-50<br />

ACO-51201L (Absorbent) 0.5 5-50<br />

OS-51288 1858<br />

Coalescer/<br />

Separator<br />

Flow Rate<br />

(GPM)<br />

Mo-gas AC-51205 1582 Aquacon ® 5 5-50<br />

AD-51225 1655 (Absorbent) 25 15-50<br />

Dirt & Free<br />

Diesel (1) water<br />

Coalescer/<br />

OS-51286 2118<br />

5 5-18<br />

Separator<br />

Biodiesel AD-51225 1655<br />

Aquacon ®<br />

(Absorbent)<br />

0.5<br />

25 15-50<br />

Jet: 5-35<br />

Avgas: 5-45<br />

AC-51205 1582<br />

5 Varies with oil<br />

Oils<br />

Aquacon<br />

AD-51225 1655 ®<br />

25 viscosity (2)<br />

(Absorbent)<br />

Solvents ASL-51201 1692 1 5-50<br />

ALL<br />

Jet Fuel &<br />

Avgas (1)<br />

Motor<br />

Gasoline<br />

Dirt<br />

FO-512PL1/2<br />

FO-512PL05 1549 Paper <strong>Filter</strong> 5<br />

0.5<br />

FO-512PL25 25<br />

FOS-512PL25 1734 Synthetic <strong>Filter</strong> 25<br />

ACO-52401L 1681<br />

0.5 10-100<br />

AC-52405 1582 5 10-100<br />

Fuels: 5-50<br />

Oils: Varies with<br />

oil viscosity (3)<br />

Diesel (1) Dirt & Free AD-52425 1655 Aquacon ® 25 30-100<br />

Biodiesel<br />

water<br />

(Absorbent)<br />

AC-52405 1582 5<br />

Varies with<br />

viscosity<br />

Oils<br />

See Form<br />

AD-52425 1655 25<br />

#1709<br />

Solvents ASL-52401 1692 1 10-100<br />

ALL<br />

Dirt<br />

FO-524PL1/2<br />

FO-524PL05 1549 Paper <strong>Filter</strong> 5<br />

0.5<br />

FO-524PL25 25<br />

2-100<br />

NOTES:<br />

(1) For aviation and diesel fuel applications, always install a differential pressure gauge or other means of determining<br />

differential pressure.<br />

(2) See Data Sheet #1709 for absorbent cartridge (AC, AD) flow rates.<br />

(3) See Data Sheet # 1532 for paper filter (FO) flow rates, see Data Sheet # 1747 for synthetic filter (FOS) flow rates.<br />

Please consult installation instructions and operating procedures that accompany products for more<br />

detailed information.


SPECIFICATIONS<br />

<strong>Filter</strong> Housing VF-61, VF-61E, VF-62<br />

• Maximum Operating Pressure: 150 psi<br />

• Inlet/Outlet Connection: 1½” NPT<br />

• Closure Seal: Buna-N O-Ring (P/N G-0986)<br />

• ⅛” brass petcock vent valve and ½” drain valve<br />

• Material:<br />

»»<br />

VF-61, VF-62: Die cast aluminum head and<br />

closure clamp assembly; carbon steel shell with<br />

epoxy coated exterior and interior.<br />

»»<br />

VF-61E: Die cast aluminum head; stainless<br />

steel band clamp; carbon steel shell with epoxy<br />

coated exterior and interior.<br />

• Weight:<br />

»»<br />

VF-61: 10 lbs., Shipping Weight: 12lbs.<br />

»»<br />

VF-61E: 8 lbs., Shipping Weight: 10 lbs.<br />

»»<br />

VF-62: 16 lbs., Shipping Weight: 18 lbs.<br />

Cartridges<br />

• Maximum Operating Temperature: 200°F<br />

• Collapse Strength: 75 psi (5 bar)<br />

• pH Range: 5 - 9<br />

• Nominal Filtration Efficiency: 98%<br />

OPTIONS<br />

• Part Number 554Y020 is a Carbon Steel 1 /2” NPT<br />

Ball Valve, with Mounting Nipple<br />

• Part Number CK-1488 quick release hand bolts<br />

(set of 4) to replace closure bolts (as shown on<br />

page 2) VF-61 and VF-62 only.<br />

• Part Number 10678 Differential Pressure Gauge<br />

Assembly (See Form #1959)<br />

DIFFERENTIAL PRESSURE GAUGE<br />

Color Indicates<br />

Pressure Drop<br />

Green: Clean 0 - 15 psi<br />

Red: Change 16 - 25 psi<br />

ORDERING INFORMATION<br />

• Specify Model VF-61, VF-61E, or VF-62 <strong>Filter</strong><br />

Housing<br />

• Unit is supplied with G-0986 Buna-N O-Ring and<br />

1<br />

/8” valve and 1 /2” drain plug installed. 1 /2” petcock<br />

drain valve is shipped loose.<br />

• Cartridges are not supplied and must be ordered<br />

separately.<br />

• Viton O-Rings (P/N G-0986A) are available but must<br />

be ordered separately. They are recommended for<br />

gasoline and solvent applications.<br />

RECOMMENDED SPARES<br />

• 1 each G-0986 Buna-N O-Ring<br />

• If Viton O-Rings are desired, 2 each G-0986A<br />

• 6 each Cartridges<br />

P/N 10678<br />

OVER PRESSURE PROTECTION<br />

When exposed to a high concentration of water, the<br />

differential pressure across an absorbent cartridge (AC,<br />

ACO, AD, or ASL Series cartridges) will immediately<br />

increase. Pressure bypasses or other means to limit the<br />

inlet pressure to 75 psi (5 bar) should be installed to prevent<br />

cartridge from collapsing.<br />

CAUTION<br />

To protect the fuel system, including the filter<br />

housing & other components, be sure to install<br />

pressure relief valve(s).<br />

CAUTION<br />

Do not use Aquacon ® absorbent cartridges (AC, ACO,<br />

AD or ASL Series) with pre-mixed jet fuel containing<br />

anti-icing additives, or with gasoline/alcohol blends.<br />

<strong>Velcon</strong> products are sold and serviced by a world-wide representative<br />

network. To order, contact Headquarters or your LOCAL REPRESENTATIVE:<br />

Due to <strong>Velcon</strong> <strong>Filter</strong>s’ continuing product improvement, drawings, specifications and pictures are subject to change without notice.<br />

COMPANY HEADQUARTERS:<br />

<strong>Velcon</strong> <strong>Filter</strong>s, LLC<br />

1210 Garden of the Gods Road<br />

Colorado Springs, CO 80907-3410<br />

Phone: 1.800.531.0180 / 1.719.531.5855<br />

Fax: 719.531.5690<br />

e-mail: vfsales@velcon.com<br />

www.velcon.com<br />

MANUFACTURING PLANTS LOCATED AT:<br />

Colorado Springs, Colorado<br />

Sylacauga, Alabama<br />

Henryetta, Oklahoma<br />

OFFICES AND AFFILIATES IN:<br />

Canada, Germany, Singapore, & Spain<br />

Liquid Filtration<br />

and Separation<br />

Specialists

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!